Product Details:
Features
Various functions with Compact and light design
Monopolar cut ( Pure cut , Blend 1 ,Blend 2 ,Blend 3 )
Monopolar Coag ( Fulguate Coag, Contact Coag, Spray Coag)
Bipolar Coag, fully meet different surgery need.
Tissue Monitoring Technology
This technology monitors the tissue density, especially for polypectomy & papillotomy, cutting is smartly divided in
cut & pause, so that coagulation occurs in each pause. The system is intelligent to change the pause interval as
tissue density changes, hence produces fine cutting with coagulation effect.
Patient Return Electrode Monitoring (PREM)
REM (Return Electrode Monitoring) function monitors the range of contact area between a patient and the neutral plate.
If the size is inappropriate, it automatically stop the high-frequency current with audible alarm to minimize the danger
of burning incidents.
Compatible with other surgical equipment
Endoscopy, HV Argon Plasma Coagulator, Optimum Smoke Evacuation System.
Waterproof Panel Operation
Microcomputer Auto Control; Three-zone (LED ) digital display.
Application
General Surgery, Gastroenterology , Dermatology,Vascular Surgery, Obstetrics and Gynecology, Liver surgery,
Heart/Thoracic Surgery; ORL/ ENT surgery, Minimally Invasive Surgery (MSI) Cerebral surgery, Neurosurgery,
Orthopedics & Plastic Surgery, Trans Urethral Resection (TUR) and other open surgery.
Technical Specification
Working Mode | Max Power | Peak Voltage |
Monopolar Cut | Pure cut | 300W | 1500V |
Blend 1 | 250W | 2000V |
Blend 2 | 200W | 2500V |
Blend 3 | 150W | 3000V |
Monopolar Coag | Fulgurate Coag | 120W | 4000V |
Spray Coag | 100W | 4020V |
Contact Coag | 80W | 4700V |
Bipolar Coag | Bipolar Coag | 70W | 620V |
Electrical requirement |
Operating Voltage | 220V±22V | Measuring Frequency | 530KHz±2 |
Monopolar Rate Load | 500Ω | Bipolar Rate Load | 100Ω |
Max Input Currency | 1400VA |
Environmental Conditions for Use |
Condition | Range |
Temperature | 50°C to 40°C |
Relative humidity | ≤ 95% non-condensing |
Pressure | 700 hPa to 1060 hPa |
Environmental Conditions for Transport and Storage |
Condition | Range |
Temperature | -40°C to 55°C |
Relative humidity | ≤ 93% non-condensing |
Pressure | 500 hPa to 1060 hPa |
Dimension (L×W×H) | 350mm×320 mm×100mm |
Weight | 15kg |
Standard Accessories
Code | Accessories Name | Quantity |
1 | Electrosurgical Unit | 1 |
2 | Reusable ESU Pencil | 2 |
3 | Disposable patient plate | 5 |
4 | Reusable patient plate cable | 1 |
5 | Resuable Bipolar forceps | 1 |
6 | Reusable Bipolar cable | 1 |
7 | Double Footswitch | 1 |
8 | Power cable | 1 |
9 | Service Manual | 1 |